loading

To be the brightest eyes for water quality monitoring on earth.

Online Inductive Conductivity Electrode DDG-GY 1
Online Inductive Conductivity Electrode DDG-GY 2
Online Inductive Conductivity Electrode DDG-GY 1
Online Inductive Conductivity Electrode DDG-GY 2

Online Inductive Conductivity Electrode DDG-GY

The advantage of the common electrode type is the price, but the defect of its "polarization" is too obvious. When a current passes through the electrode, an oxidation or reduction reaction occurs, thereby changing the composition of the solution near the electrode, causing a "polarization" phenomenon, resulting in crystallized scale on the surface of the electrode. If not cleaned in time, it will cause serious errors in conductance measurement, even Damaged, the service life is not satisfactory. Even with the high-frequency alternating current measurement, it only reduces the above-mentioned polarization phenomenon. In order to maintain measurement accuracy, it must be cleaned and calibrated regularly. Every time the sensor is cleaned or replaced, it must be shut down and interrupted, which affects efficiency. Therefore, most foreign equipment uses stepless sensors.

 

    oops...!

    no product data.

    Go to homepage
    Pipe installations
    Pipe threads 1 ½ or ¾ NPT
    Sensor material
    PP, PFA
    Measurement Range
    0~2000ms/cm
    Temperature
    200C
    Signal Output
    4-20mA,RS485 Modbus,0~2000mv
    Installation
    Flow-through, pipeline, Buried
    Accuracy
    ±(+25 us to measure the value of 0.5%)
    Measuring Range
    0~2ms/cm 0 ~ 10ms/cm, 0 ~ 20ms/cm, 0 ~ 200ms/cm, 0 ~ 2000ms/cm 0~10% HCL,0~10% NaOH ,25~40%NaoH,0~15%NHO3,0~30%H2SO4,92~99%H2SO4
    Communication
    RS485 Modbus,4-20mA
    Power
    12VDC

    Accurate, Portable, Easy-to-Use conductivity sensor 


    BOQU Instrument developed the new generation DDG-GY series inductive conductivity sensor overcomes many difficulties of the existing sensor, and integrates the signal processing line into an embedded integrated circuit ASIC with MCU, which has all the functions of conductivity measurement and digitization. This allows the sensor to be pre-calibrated before shipment and the calibration value is permanently stored in the probe.The working life can be over 10 years.


     

     


    


    3-gigapixel-high fidelity v2-4x (6)

    Product Display

    3-gigapixel-high fidelity v2-4x (6)
    3-gigapixel-high fidelity v2-4x (6)
    4-gigapixel-high fidelity v2-4x (3)
    4-gigapixel-high fidelity v2-4x (3)
    3-gigapixel-high fidelity v2-4x (6)
    3-gigapixel-high fidelity v2-4x (6)

    Accurate and Reliable Conductivity Measurement

    carousel-3
    Online Inductive Conductivity Electrode DDG-GY 8
    Accurate and Reliable
    CONDUCTIVITY SENSOR offers accurate and reliable measurements of conductivity levels in a laboratory setting.
    未标题-2 (16)
    Advanced Technology
    Its advanced technology and precision sensors allow for precise and consistent readings, ensuring the quality and integrity of experimental data.
    未标题-3 (10)
    User-friendly Interface
    With its user-friendly interface, this meter is the perfect solution for professionals and researchers in need of a dependable tool for their scientific work.
    未标题-4 (5)
    Durable Construction
    CONDUCTIVITY SENSOR is built with a durable construction to withstand the demands of laboratory use, ensuring long-lasting performance.

    Accurate conductivity Measurement

    • Ionic Presence: Conductivity increases with the concentration of ions, such as sodium (Na+), chloride (Cl-), calcium (Ca²+), and magnesium (Mg²+). Pure water has very low conductivity because it contains few ions.

    • Measurement Principle: Conductivity is measured by applying an alternating current (AC) through two electrodes placed in the water. The resulting current flow between the electrodes is used to calculate the conductivity.

    • Cell Constant: The geometry of the electrodes (distance and surface area) is defined by the cell constant, which is a factor in the calculation of conductivity. Different electrode configurations will have different cell constants.

    • Temperature Influence: Conductivity is temperature-dependent; as temperature increases, ion mobility increases, leading to higher conductivity readings. Therefore, measurements are often temperature-compensated.

    


    carousel-6

    Application Scenario

    Boqu Company has two factories in Shanghai with 17 years of production experience. We are the source factory, producing and selling by ourselves. We have a research and development center to develop products that meet market demand, a production line managed by 5S standards, and a professional quality inspection team. 

    Online Inductive Conductivity Electrode DDG-GY 13
    Industrial Quality Control Description
    Industrial Quality Control Description
    The device is utilized in industrial processes to monitor oxygen levels for quality control and compliance with environmental regulations.
    Online Inductive Conductivity Electrode DDG-GY 14
    water Treatment Description
    water Treatment Description
    DOS-1707 is used in wastewater treatment processes to monitor oxygen levels and ensure the efficiency of the treatment system.
    Online Inductive Conductivity Electrode DDG-GY 15
    Scientific Research Description
    Scientific Research Description
    The meter is employed in various scientific experiments and research studies to measure the amount of oxygen dissolved in different liquids.

    Material Introduction

    Conductivity SENSOR is constructed using high-quality and durable materials to ensure long-lasting and reliable performance. The product features a sleek and sturdy design, with a sensor input connector and data storage capabilities for calibration and measurement data. With its durable construction and precision engineering, Conductivity SENSOR is an essential tool for continuous monitoring of ph levels in various industries, such as environmental protection, pharmaceutical, foodstuff, running water, and many more. Boqu Instrument Co., Ltd., a leading manufacturer, is dedicated to using advanced technologies to solve environmental problems, ensuring high-quality and reliable performance for its products.



    carousel-6
    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
    Related Products
    no data
    We are a comprehensive enterprise, specializing in the R&D, design, manufacturing, sales and operation and maintenance services of water quality process monitoring instruments and sensors.
    Contact: Leon Lei
    Tel: +86 18955928790
    WhatsApp: +86 18955928790
    Company Address: No. 118 Xiuyan Road, Pudong New Area, Shanghai, zip code: 201315, China
    Copyright © 2025 BOQU | Sitemap Privacy Policy
    Contact us
    email
    contact customer service
    Contact us
    email
    cancel
    Customer service
    detect