loading

To be the brightest eyes for water quality monitoring on earth.

Quadrupole Conductivity Sensor Electrode 1
Quadrupole Conductivity Sensor Electrode 2
Quadrupole Conductivity Sensor Electrode 1
Quadrupole Conductivity Sensor Electrode 2

Quadrupole Conductivity Sensor Electrode

Technical Features OF Quadrupole Conductivity Electrode

  1. 1) The electrode is not easily polarized in a higher concentration solution.
  2. 2) It can compensate the electrode wire length without being affected by the wire length
  3. 3) Easy to maintain and easy to clean on a flat surface.
  4. 4) Used to measure the conductivity of industrial water and cooling water.

    oops...!

    no product data.

    Go to homepage
    Constant of electrode
    K = 0.5
    Storage Temp.
    0 to 70 °C
    Temp. Measure range
    0 to 110 °C
    Mob/whatsapp/skype
    OEM, ODM, Customized
    Sensor material
    POTF
    Size/Weight
    Diameter Φ30 × 190mm
    Protection Grade
    IP68
    Measurement Range
    10uS-300mS
    Temperature compensation
    NTC30K

    Accurate, Portable, Easy-to-Use conductivity sensor 

    wing and tap water and other waste water application.

    Technical Features OF Quadrupole Conductivity Electrode

    (1) The electrode is not easily polarized in a higher concentration solution.

    (2) It can compensate the electrode wire length without being affected by the wire length

    (3) Easy to maintain and easy to clean on a flat surface.

    (4) Used to measure the conductivity of industrial water and cooling water.

     


    


    1-gigapixel-scale-4_00x

    Product Display

    9087c1bc-83e1-4884-ae0c-ef5c2b12a499
    9087c1bc-83e1-4884-ae0c-ef5c2b12a499
    2-gigapixel-high fidelity v2-2x (5)
    2-gigapixel-high fidelity v2-2x (5)
    9087c1bc-83e1-4884-ae0c-ef5c2b12a499
    9087c1bc-83e1-4884-ae0c-ef5c2b12a499

    Accurate and Reliable Conductivity Measurement

    carousel-3
    Quadrupole Conductivity Sensor Electrode 8
    Accurate and Reliable
    CONDUCTIVITY SENSOR offers accurate and reliable measurements of conductivity levels in a laboratory setting.
    未标题-2 (16)
    Advanced Technology
    Its advanced technology and precision sensors allow for precise and consistent readings, ensuring the quality and integrity of experimental data.
    未标题-3 (10)
    User-friendly Interface
    With its user-friendly interface, this meter is the perfect solution for professionals and researchers in need of a dependable tool for their scientific work.
    未标题-4 (5)
    Durable Construction
    CONDUCTIVITY SENSOR is built with a durable construction to withstand the demands of laboratory use, ensuring long-lasting performance.

    Accurate conductivity Measurement

    • Ionic Presence: Conductivity increases with the concentration of ions, such as sodium (Na+), chloride (Cl-), calcium (Ca²+), and magnesium (Mg²+). Pure water has very low conductivity because it contains few ions.

    • Measurement Principle: Conductivity is measured by applying an alternating current (AC) through two electrodes placed in the water. The resulting current flow between the electrodes is used to calculate the conductivity.

    • Cell Constant: The geometry of the electrodes (distance and surface area) is defined by the cell constant, which is a factor in the calculation of conductivity. Different electrode configurations will have different cell constants.

    • Temperature Influence: Conductivity is temperature-dependent; as temperature increases, ion mobility increases, leading to higher conductivity readings. Therefore, measurements are often temperature-compensated.

    


    carousel-6

    Application Scenario

    Boqu Company has two factories in Shanghai with 17 years of production experience. We are the source factory, producing and selling by ourselves. We have a research and development center to develop products that meet market demand, a production line managed by 5S standards, and a professional quality inspection team. 

    Quadrupole Conductivity Sensor Electrode 13
    Industrial Quality Control Description
    Industrial Quality Control Description
    The device is utilized in industrial processes to monitor oxygen levels for quality control and compliance with environmental regulations.
    Quadrupole Conductivity Sensor Electrode 14
    water Treatment Description
    water Treatment Description
    DOS-1707 is used in wastewater treatment processes to monitor oxygen levels and ensure the efficiency of the treatment system.
    Quadrupole Conductivity Sensor Electrode 15
    Scientific Research Description
    Scientific Research Description
    The meter is employed in various scientific experiments and research studies to measure the amount of oxygen dissolved in different liquids.

    Material Introduction

    Conductivity SENSOR is constructed using high-quality and durable materials to ensure long-lasting and reliable performance. The product features a sleek and sturdy design, with a sensor input connector and data storage capabilities for calibration and measurement data. With its durable construction and precision engineering, Conductivity SENSOR is an essential tool for continuous monitoring of ph levels in various industries, such as environmental protection, pharmaceutical, foodstuff, running water, and many more. Boqu Instrument Co., Ltd., a leading manufacturer, is dedicated to using advanced technologies to solve environmental problems, ensuring high-quality and reliable performance for its products.



    carousel-6
    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
    Related Products
    no data
    We are a comprehensive enterprise, specializing in the R&D, design, manufacturing, sales and operation and maintenance services of water quality process monitoring instruments and sensors.
    Contact: Leon Lei
    Tel: +86 18955928790
    WhatsApp: +86 18955928790
    Company Address: No. 118 Xiuyan Road, Pudong New Area, Shanghai, zip code: 201315, China
    Copyright © 2025 BOQU | Sitemap Privacy Policy
    Contact us
    email
    contact customer service
    Contact us
    email
    cancel
    Customer service
    detect